Heating armoured Resistances with wings - Economic Range |
Tube stainless steel AISI 321, Ø 8 mm Wings of dissipation 25 X 50 mm out of zinc coated steel Supply voltage: 230 VAC Fixing by threaded bushing M12 X 1,25 out of zinc coated steel, length of the net: 8 mm
Low range charges: Primarily used for the heating of electrical equipment boxes Maximum temperature of use: 60 °C in natural convection, beyond in forced convection Insulate the electric terminals thermically for a higher use or equalizes with 125 °C Step between wings “P " = 5 mm, distance between centres “E” = 25 mm Electric connection: by terminals punts (delivered with screw M4)
Ranges average charges and high load: Primarily used for the air conditioning Maximum temperature of use: 100 °C with Squirrel fur = 2 m/s Work in ventilation forced to reach temperatures higher than 100 °C with Squirrel fur = 6 m/s with model MHC1334 Step between wings = 6,6 mm, distance between centres = 25 mm Electric connection: by threaded terminals M4 Applications: - Air conditioning - Furnaces and drying ovens - Installations of drying - Heating of cupboards and boxes electric…
Options: - Another Material (any stainless) - Another dimensional range (length: sheath + wings, diameter) - Another electric range (power, Voltage) - Another electric End fitting - Another form (sheath + wings: rounds, spiral…) according to plan
Accessory: Fixing by welded pivot - Allows to avoid the use of welding and any risk of break and oxidation - Assembly integrated at the time of the realization of the heater (to be specified with the order) |
|
|
Heating armoured Resistances with wings - Standard Range |
Range “Distance between center 25”: - Tube stainless steel AISI 321, Ø 8 mm - Supply Voltage 230 VAC - Wings of dissipation 25 X 50 mm out of zinc coated steel - Dimensions: not between wings “P” = 5 mm, distance between center “E” = 25 mm - Fixing by threaded bushing M12 X 1,25 out of zinc coated steel, length of the net 8 mm - Electric Connection by terminals punts (delivered with screw M4)
Range “Distance between center 40”: - Tube stainless steel AISI 321, Ø 10 mm - Supply Voltage 230 VAC - Wings of dissipation 40 X 70 mm out of zinc coated steel - Dimensions: not between wings “P” = 5.5 mm, distance between center “E” = 40 mm - Fixing by threaded bushing M14 X 1.25 out of zinc coated steel, length of the net 11 mm - Electric Connection by terminals punts (delivered with screw M4) - Adaptable only with pivot of fixing of longor 60 mm
Applications: - Air conditioning - Furnaces and drying ovens - Installations of drying - Heating of cupboards and boxes electric…
Options: - Another Material (any stainless) - Another dimensional range (length: sheath + wings, diameter) - Another electric range (power, Voltage) - Another electric End fitting - Another form (sheath + wings: rounds, spiral…) according to plan
Accessory: - Allows to avoid the use of welding and any risk of break and oxidation - Assembly integrated at the time of the realization of the heater (to be specified with the order) |
|
|
Heating armoured Resistance right |
Protection Sheath stainless 321 Ø 8 mm Fixing by threaded bushing M12 X 1,25 Electric connection by terminals punts
Options: - Another material - Another dimensional range (length, diameter) - Another electric range (power, Voltage) - Another electric End fitting - Another form according to plan - Electric Connection on the same End fitting - Double insulation in order to minimize the leakage currents towards the earth - Differentiated Heating (variable specific charge over the heating length) |
|
|
Heating armoured Resistance pin |
Protection Sheath stainless 321 Ø 8 mm Distance between centres 30 mm Fixing by threaded bushing M12 X 1,25 Electric connection by terminals punts Voltage standardized 230 V
Applications - Furnaces, drying ovens,… - Air conditioning - Installations of drying - Textile industrial Drying
Options: - Another Material - Another dimensional range (length, diameter) - Another electric range (power, voltage) - Another electric End fitting - Another form according to plan - Electric Connection on the same End fitting - Double insulation in order to minimize the leakage currents towards the earth - Differentiated Heating (variable specific charge over the heating length) |
|
|
|