Monoxide of carbon data logger
Télécharger la brochure détaillée

DATALOGGERS WEATHER STATION

Data Miniature Standalone Loggers of carbon monoxyde
Télécharger le PDF
>> détail du produit
Data Miniature Standalone Loggers of carbon monoxyde
1 internal sensor carbon monoxide
3 levels of selected resolution simultaneously (0-125 ppm, 0-500 ppm, 0-2000 ppm)
Electronics and sensor protected by 3 replaceable filters
Extended from measurement, resolution and accuracy in ppm: to see below table
Answer time T90 in temperature lower than 11 mn
32520 memorable values simultaneous
Posting of the selected ways
Programmable time of recording up to 1 year
Differed starting
Autonomy 1 year of normal use
Indelebile job number
Indication of the hour and the date
Loadmeter of displayable battery at the time of configuration by software
Recording mode: stop when the memory is full or uninterrupted with crushing of the old values
Non-volatile memory
Reusable at will
Lifespan of the monoxide sensor: 5 years
Maximum drift of the internal clock: ± 1 mn per week
Operating range 0 °C with +40 °C of temperature, 10 to 95% hygroscopy and 1 atm ± 10% of pressure
Software of necessary configuration: BoxCar 3.7 or BoxCar Pro 4.3 or higher version
Possible unloading on PALM using the software HandCar
Compatible with the shuttle of transport Hobo Shuttle
Compatible with adapter USB
Dimension (mm): Ep 40 - H 144 - Lar 60
Crush with easily replaceable lithium (HRB TEMP)
Possible mural fixing by screw
Level of reference of the exposures:
0-1 ppm normal
100 ppm limit of exposure
200 ppm headaches, nausea, tiredness etc.
800 ppm convulsions then died after 2 to 3 a.m.
PLATINUM RTD (PT100) PROBES | THERMOCOUPLE TEMPERATURE PROBES | DATALOGGERS WEATHER STATION | HEATING RESISTANCES REGULATION | WEATHER STATION AND MICROCLIMATE STATION | MOBILE MEASURING | MEASURING TRANDUCERS AND GALVANIC INSULATORS | CONTROLLERS AND INDICATORS AND THERMOSTATS | ACQUISITION AND MONITORING | SENSOR TRANSMITTER |

Homepage - Who are we ? - Request for documentation - Downloads - Contact - Newsletter - My basket
Seacrh Families - Advanced search
Equipement et matériel pour les audits énergétiques

PROSENSOR 15, rue de Montvaux 57865 Amanvillers - FRANCE
Phone  (33) 03 87 53 53 53 - Fax (33) 03 87 53 53 55
Website: www.prosensor.com - Email: info@prosensor.com

Realization: netcomposant
W3C GANDI SSL