The new logger Hobo FlexSmart is a system of data record reconfigurable and modular for applications of industrial monitoring and energy. The system 15 ways allows to the professionals management of energy and service to answer quickly and easily many applications of monitoring without necessarily having to buy a complete set of loggers. Innovating, the modules of signal processing enclipsables convert the signals of practically any type of probe; the preset probes Smart “plug and play” as well as the powerful HOBOware software ensure of the easy and fast deployments 1 to 15 ways of data 6 inputs Smart sensors “plug and play” (automatic identification) of temperature, hygroscopy, pulsations 3 slots for connection optional modules Analogical FlexSmart and True RMS Modulate FlexSmart Analogical 2 ways - Input sensors 0-20mA and 0-20VDC - Accuracy ± 0.25% of 50mV at EP - Power excitation sensor 12 VDC provided by the logger, with programmable time of heating Modulate FlexSmart True RMS 2 ways - Accepts in input the converters of current AC (CT) and/or voltage (Pt) - Measurements specifies sinusoidal and nonsinusoidal signals The configuration remains preserved in the FlexSmart modules Great non-volatile memory size of 512k allowing long-term recordings Flexibility of the possibilities of power: internal batteries, external, and/or transformer battery mains AC Robust case with necessary of fixing in option Measurements - Temperature - Relative Humidity - current AC (True RMS) - voltage AC (True RMS) - kw - kWh - Pressure - Differential Pressure of Air - CO2 - Inputs Impulses for flowmeter - Any other sensor with output 4-20mA/0-20 VDC - Sensors Weather
Applications - Research & control/Building - Audits of energy - Diagnostic HVAC/R (heating, ventilation, air conditioning, refrigeration) - Measurements and Checks energy saving - Startup of the buildings - Checking of outputs - Studies systems of Compressed air - Control of the environment - Classification of equipment - Detection of intermittent defect - Setting in conformity according to polycies and standards - Studies quality of the air - Monitoring of state of machine FlexSmart modules The optional modules FlexSmart True RMS and Analogique assembled on the higher face of the logger ensure a maximum flexibility. These modules two-track make it possible to incorporate converters of current AC or voltage, or sensors with output 0-20mA or 0-20 VDC. Each way can be configured separately. The FlexSmart module provides a power of excitation of 12V and a time of heating of the configurable sensor by the user Modulate FlexSmart TRMS (ref. S-FS-TRMSA) - current AC (True RMS) - voltage AC (True RMS) Modulate analogical FlexSmart (ref. S-FS-CVIA) - kw - Manometric Pressure - Differential Pressure of air - Carbon dioxide - Relative Humidity Temperature assembly drain - Any sensor with output 4-20mA or 0-20 VDC (appropriate to the sensors 2,5V; 5V and 10V) |