Brass thermowell – DGL12-100 |
Gaine de protection en laiton Ø9 mm Raccord 1/2" gaz cylindrique Entrée Ø14 sur 11 mm Vis de blocage M3 Longueur utile : 100 mm |
|
|
Stick silicone transparent - tube of 90 ml |
For the sealing off, joining and coatings Ready for use Hardening with moisture Permanent flexibility with high and low temperatures Age-resistant and UV Maximum temperature of use: +220 °C |
|
|
Termowell screw-in tack welded |
Protection sheath stainless steel 316 L, Ø 13,5 X 2,3 mm or Ø 9 X 1 mm Connection 1/2 " cylindrical gases socket, 1/2 " plug cylindrical gases For probe of Ø 8 mm (“Ød” = 13 mm) or of Ø 6 mm (“Ød” = 9 mm) The working length of the spike is equal to the working length of the sensor minus 20 mm possible Covering PFA, halar, etc… operating Pressure: 100 bar up to 20 °C 70 bar up to 400 °C |
|
|
Termowell screw-in tack welded with latch-tightening screw |
Protection sheath stainless steel 316 L, Ø 13,5 X 2,3 mm or Ø 9 X 1 mm Latch-tightening screw Connection 1/2 " plug cylindrical gases For probe of Ø 6 to 8 mm The working length of the spike is equal to the working length of the sensor minus 10 mm possible Covering PFA, halar, etc… operating Pressure: 100 bar up to 20 °C 70 bar up to 400 °C |
|
|
Termowell screw-in drilled in the earth standardized |
Protection sheath stainless steel 316 L, Ø 16 mm Connection 1/2 " cylindrical gases socket, 1/2 " NPT or 3/4 " NPT For probe of Ø 6 to 8 mm The working length of the spike is equal with the working length of the sensor minus 50 mm Possible covering halar (fluomère) on plunger Pressure operating: 100 bar up to 20 °C 70 bar up to 400 °C Another length on request |
|
|
Termowell screw-in tack welded |
Protection sheath stainless steel 316 L, Ø 13,5 X 2,3 mm or Ø 9 X 1 mm Connection 1/2 " cylindrical gases socket Cone to weld Ø 30 to 25 mm For probe of Ø 6 to 8 mm The working length of the spike is equal to the working length of the sensor minus 20 mm |
|
|
Lubricate silicone heat-conducting |
Electric grease silicone heat-conducting insulating is used to conduct the heat by filling space between various materials does not harden, resists water, not corrosive Temperature of use: -60 to + 205 °C Conservation: > 1 year at temperature lower than 50 °C Solvent: trichloréthane |
|
|
Miniature connector compensated thermocouple |
Material: thermoplastic high temperature armed with glass fiber, able to tolerate a temperature of 200 °C uninterrupted Facilitated connection of wire The indication of polarity avoids any error of connection Accept wire of a diameter from 0,002 to 0,6 mm The maximum diameter external of the cable is 4,5 mm Accessory: cable clamp stainless steel, reference SCM |
|
|
Connector compensated standard thermocouple |
Material: thermoplastic high temperature armed with glass fiber, able to tolerate a temperature of 200 °C uninterrupted Facilitated connection of wire The indication of polarity avoids any error of connection Accept wire of a diameter from 0,2 to 2,0 mm The maximum diameter external of the cable is 8 mm Accessory: cable clamp stainless steel, reference SCS |
|
|
Miniature base plate thermocouple enclipsable |
casing: thermoplastic high temperature armed glass fiber, able to tolerate a temperature of 200 °C uninterrupted Facilitated connection of wire Colors standards Cut out panel: 17 mm X 8 mm |
|
|
Base plate standard thermocouple enclipsable |
casing: thermoplastic high temperature armed glass fiber, able to tolerate a temperature of 200 °C uninterrupted Facilitated connection of wire Colors standards Cut out panel: 26 mm X 13 mm |
|
|
Duplex connector compensated standard thermocouple |
Material: thermoplastic high temperature armed with glass fiber able to tolerate a temperature of 220°C uninterrupted Facility of connection of wire Inversion of polarity made impossible by locating pin Accept wire of 0.2à 2 mm Maximum diameter external of the cable is 8 mm Closing of the lid ensured by a screw |
|
|
|